HLxxWIN Datalogger Support Software:
a. Program Editor
b. Real Time Monitor Mode
c. Terminal emulator
d. Auto-polling for multiple remote stations
e. Communication supports
f. Simple operation mode

TERM8W Datalogger Support Software:
a. Windows® Graphic Interface
b. Charts, Graphs and Reports
c. Wind Rose Charts
d. Database Editor
e. Program Editor
f. Auto Polling - Unlimited Remote Sites
g. Real Time Data Values and Real Time Gauges Display
h. Foreign languages

HLxx Light Datalogger Support Software:
a. Program Editor
b. Real Time Monitor Mode
c. Terminal emulator
d. On-line new & history data view
e. Communication supports
f. Simple operation mode

HL20 Data acquisition system:
a. 20 single-ended or 8 differential analog input channels
b. Expandable to more than 200 channels
c. 4 excitation voltage outputs
d. 4 pulse input channels
e. 6 digital control outputs
f. Low power consumption
g. Optional EEDSU data storage unit

HL20-A Data acquisition system:
a. 20 single-ended or 8 differential analog input channels
b. Expandable to more than 200 channels
c. 4 excitation voltage outputs
d. 4 pulse input channels
e. 6 digital control outputs
f. Low power consumption
g. Optional EEDSU data storage unit

EEDSU Data Storage Unit:
a. Data storage capacity : > 350,000,000 data points
b. Power requirements : 12VDC ( 7 to 30 VDC )
c. Power consumption : < 15mA ( @12.6VDC ) in average.
d. Baud rate : Data transfer is 9,600 baud.
e. Temperature operating range : -25℃to +70℃
f. Dimension : 6.7cm * 6.7cm * 2.8cm

CEM416A Channel expansion module:
a. 48 single-ended or 32 differential input channels
b. 16 full bridge input channels

VWA-1 VW to Analog Converter:
a. Frequency range: 400 – 6000 HZ
b. Resolution: 24 bits
c. Response time: @ 0.5S ( @ 500mS ) after power-on
d. VW to Analog channel no.: 1 channel (VW)
e. Analog output: 0 – 2 VDC (VW)
f. Power requirement: 9 – 15 VDC
g. Dimension: @ 16 cm (L) x 6 cm (W ) x 2.7 cm (H)

HP2 Power Switch Module:
a. Channel number: 2
b. Control principle: none-contact switch
c. Control voltage: High: 5 VDC, Low: 0 VDC
d. Input power: 12 VDC ( < 50 VDC )
e. Output power: 12 VDC
f. Current drain: < 0.05 mA
g. Nominal load: < 1.5 A @12VDC

VS7 Logger & sensor series:
a. 5 analog input channels
b. 2 potentiometer input channels
c. 3 pulse input channels
d. 2 continuous 5V & 12V power outputs
e. 16 characters by 2 line LCD display w/3 buttons
f. Adjustable logging interval from 2s up to 10+ hrs
g. 2 gigabyte or 512 megabyte data storage ( SD Card )

EE-04 Wind Sensor:
a. Measuring range:Wind speed: 0 - 75 m/s
                                    Wind direction: 0 - 360 °
b. Accuracy: Wind speed: ±1 m/s( 0-20m/s )
                                                ±5% ( >20m/s )
                         Wind direction: ±7 °
c. Signal output: Wind speed: magnetically switch
                              Wind direction: potentiometer

03002 Wind Sentry Anemometer and Vane:
a. Measuring range: Wind speed: 0 – 50 m/s
                                    Wind direction: 0 – 360 °
b. Accuracy: Wind speed: ± 0.5 m/s
                        Wind direction: ± 5 °
c. Signal output: Wind speed: magnetically induced AC voltage
                              Wind direction: potentiometer
d. Options: 03002V WS&WD: 0 – 1 VDC outputs
                     03102V WS: 0 – 1 VDC output
                     03302V WD: 0 – 1 VDC output

05103 Wind monitor:
a. Measuring range: Wind speed : 0 - 100 m / s
                                    Wind direction : 0 - 360°
b. Accuracy:              Wind speed : ± 0.3 m / s or 1% of reading
                                    Wind direction : ± 3°
c. Signal output:       Wind speed : magnetically induced AC voltage
                                    Wind direction : DC voltage - potentiometer
d. Options : 05103V with 0 - 5 VDC outputs
                      05103L with 4 - 20 mA outputs

MP101A Temp. / RH probe:
a. Measuring range:
    Temperature : -40℃ - +60℃
    Humidity : 0 - 100%
b. Accuracy:
    Temperature : ± 0.3℃
    Humidity : ± 1.5% ( 10 - 95% )
                       ± 2.5% ( <10% or > 95% )

111N&222N Temp./RH probes:
a. Measuring range:
    Temperature: -40 ℃ to + 60 ℃
    Humidity: 0 - 100 %
b. Accuracy:
    Temperature: ± 0.3 ℃ (-20 ℃ to + 40 ℃ )
                            ± 0.5 ℃ (-40 ℃ to + 60 ℃ )
    Humidity: ± 3 % (0 - 90 %)
                       ± 5 % (90 - 98 %)

TH-46 Temp./RH probe:
a. Measuring range:
    Temperature: -40 ℃ to + 60 ℃
    Humidity: 0 - 100 % RH
b. Accuracy:
    Temperature: ± 0.15 ℃
    Humidity: ± 1.0 % RH

HC2S3 Temp./RH probe:
a. Measuring range:
    Temperature: -40 ℃ to + 60 ℃
    Humidity: 0 - 100 % RH
b. Accuracy:
    Temperature: ± 0.1 ℃ at 23℃
    Humidity: ± 0.8 % RH at 23℃

888 & 884 Solar radiation shields:
a. Material: UV stabilized white thermoplastic plates
b. Principle: Natural ventilation
c. No power required
d. 888: 8 plates
e. 884: 4 plates

888A & 884A Solar radiation shields:
a. Material: UV stabilized white thermoplastic plates
b. Aspiration: Electronic fan
c. Temperature range: -40℃ to +70℃
d. Power requirement: 12VDC
e. Cable length: 5M or 10M

E20 Sillicon pyranometer:
a. Spectral range: 400 - 1100 nm
b. Sensitivity:  33 uV / W / m2
c. Linearity:  1% up to 3000 W / m2
d. Accuracy: ± 3 %
e. Response time: typical 3 uS

LP02 Pyranometer:
a. Spectral response: 305 - 2800 nm
b. Sensitivity: 10 - 40 uV/ W/ m2
c. Non - stability: < 1% change per year
d. Non -Linearity: ± 2.5 %
e. Response time 95 % : 18 Sec
f. Temperature range: -40 ℃ to + 80 ℃

SR11 First Class Pyranometer:
a. ISO classification: First Class
b. Spectral response: 305 – 2800 nm
c. Sensitivity ( nominal ): 15 uV/W/m2
d. Range: 0 – 2000 W/m2
e. Temperature dependence: < 0.1%/℃
f. Temperature range: -40℃ to +80℃
g. Calibration traceability: WRR

NR01 & RA01 Net Radiation – Pyrgeometer sensors
NR01 & RA01 Specs:

General:
a. Temperature range: -40℃ to +80℃
b. Range: 0 – 2000 W/m2
c. Temperature sensor: Thermister
d. Temperature sensor: users own preference can be plugged in
Pyranometer ( Short Wave ):
a. Pyranometer ISO classification: Second Class
b. Spectral response: 305 - 2800 nm
c. Calibration traceability: WRR
Pyrgeometer ( Long Wave ):
a. Spectral response: 4500 – 50000 nm
b. Calibration traceability: NIST
c. Window heating offset @ 1000 W/m2 solar radiation: < 15 W/m2
d. Heating power: 5 Watt @ 12VDC

MS-020VM Pyranometer:
a.Spectral response: 400 – 1100 nm
b.Signal output: 0 – 1 VDC
c.Measuring range: 0 – 1400 W/ ㎡
d.Accuracy: < 4%
e.Response time: < 50 ms
f.Power supply: 12 – 24 VDC/7mA

BP0611A Barometric Pressure sensor:
a.Measuring range:630 – 1130 mBar or hPa ( 18.6 – 33.4in. Hg ).
b.Resolution: Infinite.
c.Operating Temp.:-40ºC to + 85ºC.
d.Temp. Compensatedrange: 0ºC to + 70ºC.
e. Accuracy: ±0.125% FS
f.Power requirement:10 – 24VDC.
g. Current Consumption: Active 5mA @12VDC
                                             Static 1.1mA @12VDC.
h.Signal output: 0 - 2 VDC.

E90 Quantum sensor:
a. Spectral range:  400 - 700 nm
b. Sensitivity:  1.0mV  per 1000 umols-1m-2
c. Linearity:  1 %  up  to  10,000 umols-1m-2
d. Accuracy:  ± 4 %
e.Stability: < ± 2 %  change over a 1 year period
f. Response time: typical 1 uS

Q*7.1 Net Radiometer:
a.Spectral response: 0.25 to 60 um
b.Nominal resistance: 4 ohms
c.Windshields: 0.25mm thick polyethylene
d.Time constant: Approx. 30 seconds
e. No power required.

SKR110 Red / Far Red sensor:
a. Narrow band filter centered: 660 nm and 730 nm
b. Detector: GaAsp
c. Linearity error: 0.2%
d. Absolute Calibration error: typical < 3% ( max. 5%  )
e. Longterm stability: <± 2%
f. Response time: 10 nS

SKU420 UVA sensor:
a. Spectral range:  315 - 380 nm
b. Detector: GaAsp
c. Linearity error: better than 1%
d. Absolute Calibration error: typical < 3%  ( max. 5%  )
e. Longterm stability: < ± 2%
f. Response time: 10 mS

SKU430 UVB sensor:
a. Spectral range: 280 - 315 nm
b. Detector: GaAsp
c. Linearity error: better than 1%
d. Absolute Calibration error: typical < 3% ( max. 5% )
e. Longterm stability: < ± 2%
f. Response time: 10 mS

SKU440 UV Index Sensor:
a. Spectral range: 280-315 nm
b. Detector: Filtered TiO2 Photodetector
c. Linearity error: Better than 1 %
d. Absolute calibration error: typical < 3 % ( max. 5 % )
e. Longterm stability: < ±2 %
f. Response time: Better than 50 mS

HFP01 Heat flux plate:
a. Sensitivity: 50 uV / W / m2
b. Resistance ( nominal ): 2 Ω
c. Measuring range: +2000 to -2000W / m2
d. Temperature dependence: < 0.1% / ℃
e. Response time: ± 4 min ( equals soil )

HFT-3 Soil Heat Flow Transducer:
a. Nominal calibration factor: 40 W / m2/ mV
b. Resistance ( nominal ): 2 Ω
c. Nominal Size : 38.56mm diameter * 3.93 mm thick
d. Thermal conductivity : 1.22 Wm-1K-1
e. Cable : shield 2-conductor, 7.6m long

255-100 Evaporation Gauge & 555 Evaporation Pan:
Dimension:
  a. Height: 27 1/2 inches
  b. Diameter: 8 inches
  c. Float: 4 inches diameter plastic
Potentiometer :
  a. Accuracy: 0.25 %
  b. Rotation: continuous
  c. Resistance: 1000 ohms
  d. Operating temperature: -40ºC - +60ºC

Globe-Thermometer:
a. Measuring range: -40℃ to +60℃
b. Accuracy: <±0.3℃ ( –20 to +40℃ ) ; <±0.5℃ ( –40 to +60℃ )
c. Diameter: 150 mm ( included with a 111S-5 temp. probe )
d. Accessories: suspended wires & a mounting stand included
e. Compatible dataloggers: HL10, HL20, DT12 and other brand of dataloggers
f. Installation is easy and simple

111S Surface Temperature Probe:
111S Surface Temperature Probe:
a. Measuring range: -40℃ to +60℃
b. Accuracy: ±0.3℃ ( -20℃ to +40℃ )
                        ±0.5℃ ( -40℃ to +60℃ )
c. For measurement of panel or leaf or other surface temperature

111S-H Surface or Panel Temperature Probe:
111S-H Surface Temperature Probe:
a. Measuring range: -40℃ to +90℃
b. Accuracy: ±0.3℃ ( -20℃ to +40℃ )
                        ±0.5℃ ( -40℃ to +100℃ )
c. For measurement of panel or leaf or other surface temperature

IRR-P Infrared Radiometer:
a. Field of View ( FOV ) : 22 ° half angle
b. Accuracy : -15 to +60 °C   ±0.2 °C   absolute accuracy
                                                  ±0.1 °C   uniformity and repeatability
                        -55 to +80 °C    ±0.5 °C  absolute accuracy
                                                  ±0.3 °C   uniformity and repeatability
c. Wavelength Range : 8 - 14 um
d. Response Time : Less than 1 second
e.Operating Environment : -55°C to +80°C
                                               0 - 100 RH ( non-condensing )

111N Temperature probe:
a. Measuring range: -40℃ to +60℃
b. Accuracy: ±0.3℃ ( -20℃ to +40℃ )
                        ±0.5℃ ( -40℃ to +60℃ )
c. For measurement of air, soil and water temperature

111H Temperature probe:
a. Measuring range: - 40 ℃ to + 90 ℃
b. Accuracy: ± 0.3 ℃ ( - 20℃ to + 40 ℃ )
                        ± 0.5 ℃ ( - 40℃ to + 60 ℃ )
                        ± 0.7 ℃ ( + 60 ℃ to + 90 ℃)

LWS Leaf Wetness Sensor:
a. Wet/Dry threshold : A defined resistance in K Ohm
b. Time of Wetness : Wet fraction in datalogger's recording interval
c. Power requirement: Excitation voltage ( 1 - 5 VDC )
d. Dimension: 11.5 cm ( L ) x 5.4 cm ( W )
e. Accessory: Stainless steel sensor mounting bracket included

SF AMP Sap Flow Converter:
a. IN / OUT channel number: 3
b. Input range: -1000 to + 1000 uV
c. Output range: -2000 to + 2000 mV
d. Input channel type: Differential signal x 3
e. Output channel type: Single - ended signal x 3
f. Amplification: 2000 x ± 1 %
g. Power supply: 8 - 24 VDC
h. Power consumption: @ 15mA
i. Enclosure: IP65

TK-1 Rain gauge:
a. Sensor type: tipping bucket
b. Orifice diameter: 200 mm
c. Material: Bronze
d. Sensitivity: 0.5 mm
e. Accuracy: below 20mm/hr ± 0.5mm
                        20mm/hr to 120 mm/hr ± 3%
f. Signal output: none contact reed switch
g. Housing: stainless steel
h. Air bubble leveling included

ARG100 Aerodynamic rain gauge:
a. Funnel diameter: 254 mm ( 10 inches )
b. Sensitivity: 0.2 mm per tip
c. Output: contact closure
d. Power requirement: None
e. Air bubble for leveling included

6463M/I Rain gauges:
a. Sensor type: tipping bucket
b. Sensitivity: 0.2 mm ( M Series ) ; 0.01 inch ( I Series )
c. Output: contact closure
d. Housing material: UV stabilized ABS plastic
e. Power requirement: None
f. Air bubble for leveling included
g. Bird spikes included

260-700 Ultrasonic Water Level or Snow Depth Sensor:
a. Measuring range: 0.5 to 10 meters
b. Beam width: 22 degree
c. Accuracy: ± 1cm or 0.4% distance to target
d. Resolution: 3 mm
e. Temperature range: -30 ℃ to +70 ℃
f. Analog output: 0 – 2 VDC or 0 – 5 VDC
g. Power: 12 to 24 VDC, 50 mA

WL400 Submersible pressure transducers:
a. Measuring range: 0 - 15' ( others: 0 - 30' , 0 - 60' , .... )
b. Burst Pressure: 10 * Full scale range
c. Static accuracy: ± 0.2 % F.S.R.
d. Power requirement: 10 - 36 VDC
e. Housing Material: SS304L Stainless Steel
f. Output: 0.4 to 0.2 VDC ( or 4 - 20 mA)
g. Cable Length: 7.5M or 15M or 30M standard

720 Submersible pressure transducers:
a. Measuring ranges: 0 - 5 through 0 - 300 psi
b. Burst pressure: 2.0 * F.S.
c. Static accuracy: ± 0.25% F.S.R.
d. Power requirement: 9 - 30 VDC
e. Wetted material: SS316
f. Operating temp. range: -10ºC to +60ºC
g. Compensated temp.range: 0ºC to +50ºC
h. Output: 0.4 to 2.0 VDC or 4 - 20 mA
i. Circuit Protection: Polarity, surge/shorted output

PM-S20 & PM-S10 Solar panels:
a. Max. power: 21Watt (PM-S20) ; 10Watt (PM-S10)
b. Voltage at peak: 17.4 VDC (PM-S20) ; 16.8 VDC (PM-S10)
c. Current at Peak: 1.21A (PM-S20) ; 0.74A (PM-S10)
d. Optional USM 20 / USM 10 mounting bracke

200SS Watermark soil moisture sensor:
a. Measuring range: 0 to 2 Bar ( 0 - 200 Centibars )
b. Fully solid state
c. Will not dissolve in soil
d. Linear accuracy even in moist soils ( below 50 Centibars )
e. Not affected by freezing temperatures
f. Internal compensation for commonly found salinity levels

30KTCD-NL Watermark digital meter:
a. Digital readout
b. Converts electrical resistance reading to centibars
c. Accuracy and stability
d. One meter reads all watermark sensors

PSM Portable Soil Moisture Measurement System:
a. Digital LCD display
b. Measuring range: 0 – 100% VWC
c. Accuracy and stability
d. Included with AC/DC power supply and instrument case

AVM Portable anemometer:
AVM-01 & AVM-03
a. Measuring range: 0 - 45 m / s ( 0 - 88 KNOTS, 0 - 100 MPH )
b. Accuracy: ± 3%
c. Resolution: 0.1
d. Display: 3 1/2 digit LCD
e. Operating temperature: 10℃ to 50℃
f. Power source: 9V battery
g. Weight: 500g

AVM-03
a. Temperature: 0 - 60℃ ( 32℉ - 140℉ )
b. Accuracy: ± 0.8℃ ( ± 1.5℉ )

HT800 Portable thermo-hygrometer:
a. Measuring range:
    Temperature: -15℃ - +60℃
    Humidity: 5 - 98%
b. Accuracy:
    Temperature: ± 0.2℃ ( ± 0.4℉ )
    Humidity: ± 2.5%
c. Resolution:
    Temperature: 0.1℃ ( 0.1℉ )
    Humidity: 0.1% RH
d. Display: digital LCD display
e. Measuring rate: 2.5 per second
f. Power source: 9V battery

LM-SS Portable Light Meter For Solar Sensors:
a. Available sensors including: E20, LP02, SR11, PSP, LI-200S,
    CM3, E90, LI-190S, LI-210S, PIR, TUVR, CM4, CMP series,
    SP-Lite, NR-Lite, PAR Lite, CUV4 and other sensors with
    low signal outputs.
b. A/D resolution: 16 bits
c. Input range ( programmable ): ±200mV ( 10 uV resolution )
                                                         ±100mV ( 10 uV resolution )
                                                         ±50mV ( 10 uV resolution )
                                                         ±25mV ( 1 uV resolution )
                                                         ±12.5mV ( 1 uV resolution )
                                                         ±6.25mV ( 1 uV resolution )
d. Accuracy: 0.1%
e. Display: LCD 4 digits with sign
f. Battery: 2 AA alkaline
g. Data logger memory: more than 3500 samples
h. Data logger storage interval: 2..65535 seconds
i. Accessories: carrying case, USB connection cable & software included

Sap Flow Monitoring System:
a. Two-needle type of sap flow sensor
b. Needle length: 33mm standard
c. Heating ( constant current source ): 0.2 Watt
d. Power : 12 VDC
e. Data acquisition system

products