HLxxWIN Datalogger Support Software: a. Program Editor b. Real Time Monitor Mode c. Terminal emulator d. Auto-polling for multiple remote stations e. Communication supports f. Simple operation mode | |
TERM8W Datalogger Support Software: a. Windows® Graphic Interface b. Charts, Graphs and Reports c. Wind Rose Charts d. Database Editor e. Program Editor f. Auto Polling - Unlimited Remote Sites g. Real Time Data Values and Real Time Gauges Display h. Foreign languages | |
HLxx Light Datalogger Support Software: a. Program Editor b. Real Time Monitor Mode c. Terminal emulator d. On-line new & history data view e. Communication supports f. Simple operation mode | |
HL20 Data acquisition system: a. 20 single-ended or 8 differential analog input channels b. Expandable to more than 200 channels c. 4 excitation voltage outputs d. 4 pulse input channels e. 6 digital control outputs f. Low power consumption g. Optional EEDSU data storage unit | |
HL20-A Data acquisition system: a. 20 single-ended or 8 differential analog input channels b. Expandable to more than 200 channels c. 4 excitation voltage outputs d. 4 pulse input channels e. 6 digital control outputs f. Low power consumption g. Optional EEDSU data storage unit | |
EEDSU Data Storage Unit: a. Data storage capacity : > 350,000,000 data points b. Power requirements : 12VDC ( 7 to 30 VDC ) c. Power consumption : < 15mA ( @12.6VDC ) in average. d. Baud rate : Data transfer is 9,600 baud. e. Temperature operating range : -25℃to +70℃ f. Dimension : 6.7cm * 6.7cm * 2.8cm | |
CEM416A Channel expansion module: a. 48 single-ended or 32 differential input channels b. 16 full bridge input channels | |
VWA-1 VW to Analog Converter: a. Frequency range: 400 – 6000 HZ b. Resolution: 24 bits c. Response time: @ 0.5S ( @ 500mS ) after power-on d. VW to Analog channel no.: 1 channel (VW) e. Analog output: 0 – 2 VDC (VW) f. Power requirement: 9 – 15 VDC g. Dimension: @ 16 cm (L) x 6 cm (W ) x 2.7 cm (H) | |
HP2 Power Switch Module: a. Channel number: 2 b. Control principle: none-contact switch c. Control voltage: High: 5 VDC, Low: 0 VDC d. Input power: 12 VDC ( < 50 VDC ) e. Output power: 12 VDC f. Current drain: < 0.05 mA g. Nominal load: < 1.5 A @12VDC | |
VS7 Logger & sensor series: a. 5 analog input channels b. 2 potentiometer input channels c. 3 pulse input channels d. 2 continuous 5V & 12V power outputs e. 16 characters by 2 line LCD display w/3 buttons f. Adjustable logging interval from 2s up to 10+ hrs g. 2 gigabyte or 512 megabyte data storage ( SD Card ) | |
EE-04 Wind Sensor: a. Measuring range:Wind speed: 0 - 75 m/s Wind direction: 0 - 360 ° b. Accuracy: Wind speed: ±1 m/s( 0-20m/s ) ±5% ( >20m/s ) Wind direction: ±7 ° c. Signal output: Wind speed: magnetically switch Wind direction: potentiometer | |
03002 Wind Sentry Anemometer and Vane: a. Measuring range: Wind speed: 0 – 50 m/s Wind direction: 0 – 360 ° b. Accuracy: Wind speed: ± 0.5 m/s Wind direction: ± 5 ° c. Signal output: Wind speed: magnetically induced AC voltage Wind direction: potentiometer d. Options: 03002V WS&WD: 0 – 1 VDC outputs 03102V WS: 0 – 1 VDC output 03302V WD: 0 – 1 VDC output | |
05103 Wind monitor: a. Measuring range: Wind speed : 0 - 100 m / s Wind direction : 0 - 360° b. Accuracy: Wind speed : ± 0.3 m / s or 1% of reading Wind direction : ± 3° c. Signal output: Wind speed : magnetically induced AC voltage Wind direction : DC voltage - potentiometer d. Options : 05103V with 0 - 5 VDC outputs 05103L with 4 - 20 mA outputs | |
MP101A Temp. / RH probe: a. Measuring range: Temperature : -40℃ - +60℃ Humidity : 0 - 100% b. Accuracy: Temperature : ± 0.3℃ Humidity : ± 1.5% ( 10 - 95% ) ± 2.5% ( <10% or > 95% ) | |
111N&222N Temp./RH probes: a. Measuring range: Temperature: -40 ℃ to + 60 ℃ Humidity: 0 - 100 % b. Accuracy: Temperature: ± 0.3 ℃ (-20 ℃ to + 40 ℃ ) ± 0.5 ℃ (-40 ℃ to + 60 ℃ ) Humidity: ± 3 % (0 - 90 %) ± 5 % (90 - 98 %) | |
TH-46 Temp./RH probe: a. Measuring range: Temperature: -40 ℃ to + 60 ℃ Humidity: 0 - 100 % RH b. Accuracy: Temperature: ± 0.15 ℃ Humidity: ± 1.0 % RH | |
HC2S3 Temp./RH probe: a. Measuring range: Temperature: -40 ℃ to + 60 ℃ Humidity: 0 - 100 % RH b. Accuracy: Temperature: ± 0.1 ℃ at 23℃ Humidity: ± 0.8 % RH at 23℃ | |
888 & 884 Solar radiation shields: a. Material: UV stabilized white thermoplastic plates b. Principle: Natural ventilation c. No power required d. 888: 8 plates e. 884: 4 plates | |
888A & 884A Solar radiation shields: a. Material: UV stabilized white thermoplastic plates b. Aspiration: Electronic fan c. Temperature range: -40℃ to +70℃ d. Power requirement: 12VDC e. Cable length: 5M or 10M | |
E20 Sillicon pyranometer: a. Spectral range: 400 - 1100 nm b. Sensitivity: 33 uV / W / m2 c. Linearity: 1% up to 3000 W / m2 d. Accuracy: ± 3 % e. Response time: typical 3 uS | |
LP02 Pyranometer: a. Spectral response: 305 - 2800 nm b. Sensitivity: 10 - 40 uV/ W/ m2 c. Non - stability: < 1% change per year d. Non -Linearity: ± 2.5 % e. Response time 95 % : 18 Sec f. Temperature range: -40 ℃ to + 80 ℃ | |
SR11 First Class Pyranometer: a. ISO classification: First Class b. Spectral response: 305 – 2800 nm c. Sensitivity ( nominal ): 15 uV/W/m2 d. Range: 0 – 2000 W/m2 e. Temperature dependence: < 0.1%/℃ f. Temperature range: -40℃ to +80℃ g. Calibration traceability: WRR | |
NR01 & RA01 Net Radiation – Pyrgeometer sensors NR01 & RA01 Specs: General: a. Temperature range: -40℃ to +80℃ b. Range: 0 – 2000 W/m2 c. Temperature sensor: Thermister d. Temperature sensor: users own preference can be plugged in Pyranometer ( Short Wave ): a. Pyranometer ISO classification: Second Class b. Spectral response: 305 - 2800 nm c. Calibration traceability: WRR Pyrgeometer ( Long Wave ): a. Spectral response: 4500 – 50000 nm b. Calibration traceability: NIST c. Window heating offset @ 1000 W/m2 solar radiation: < 15 W/m2 d. Heating power: 5 Watt @ 12VDC | |
MS-020VM Pyranometer: a.Spectral response: 400 – 1100 nm b.Signal output: 0 – 1 VDC c.Measuring range: 0 – 1400 W/ ㎡ d.Accuracy: < 4% e.Response time: < 50 ms f.Power supply: 12 – 24 VDC/7mA | |
BP0611A Barometric Pressure sensor: a.Measuring range:630 – 1130 mBar or hPa ( 18.6 – 33.4in. Hg ). b.Resolution: Infinite. c.Operating Temp.:-40ºC to + 85ºC. d.Temp. Compensatedrange: 0ºC to + 70ºC. e. Accuracy: ±0.125% FS f.Power requirement:10 – 24VDC. g. Current Consumption: Active 5mA @12VDC Static 1.1mA @12VDC. h.Signal output: 0 - 2 VDC. | |
E90 Quantum sensor: a. Spectral range: 400 - 700 nm b. Sensitivity: 1.0mV per 1000 umols-1m-2 c. Linearity: 1 % up to 10,000 umols-1m-2 d. Accuracy: ± 4 % e.Stability: < ± 2 % change over a 1 year period f. Response time: typical 1 uS | |
Q*7.1 Net Radiometer: a.Spectral response: 0.25 to 60 um b.Nominal resistance: 4 ohms c.Windshields: 0.25mm thick polyethylene d.Time constant: Approx. 30 seconds e. No power required. | |
SKR110 Red / Far Red sensor: a. Narrow band filter centered: 660 nm and 730 nm b. Detector: GaAsp c. Linearity error: 0.2% d. Absolute Calibration error: typical < 3% ( max. 5% ) e. Longterm stability: <± 2% f. Response time: 10 nS | |
SKU420 UVA sensor: a. Spectral range: 315 - 380 nm b. Detector: GaAsp c. Linearity error: better than 1% d. Absolute Calibration error: typical < 3% ( max. 5% ) e. Longterm stability: < ± 2% f. Response time: 10 mS | |
SKU430 UVB sensor: a. Spectral range: 280 - 315 nm b. Detector: GaAsp c. Linearity error: better than 1% d. Absolute Calibration error: typical < 3% ( max. 5% ) e. Longterm stability: < ± 2% f. Response time: 10 mS | |
SKU440 UV Index Sensor: a. Spectral range: 280-315 nm b. Detector: Filtered TiO2 Photodetector c. Linearity error: Better than 1 % d. Absolute calibration error: typical < 3 % ( max. 5 % ) e. Longterm stability: < ±2 % f. Response time: Better than 50 mS | |
HFP01 Heat flux plate: a. Sensitivity: 50 uV / W / m2 b. Resistance ( nominal ): 2 Ω c. Measuring range: +2000 to -2000W / m2 d. Temperature dependence: < 0.1% / ℃ e. Response time: ± 4 min ( equals soil ) | |
HFT-3 Soil Heat Flow Transducer: a. Nominal calibration factor: 40 W / m2/ mV b. Resistance ( nominal ): 2 Ω c. Nominal Size : 38.56mm diameter * 3.93 mm thick d. Thermal conductivity : 1.22 Wm-1K-1 e. Cable : shield 2-conductor, 7.6m long | |
255-100 Evaporation Gauge & 555 Evaporation Pan: Dimension: a. Height: 27 1/2 inches b. Diameter: 8 inches c. Float: 4 inches diameter plastic Potentiometer : a. Accuracy: 0.25 % b. Rotation: continuous c. Resistance: 1000 ohms d. Operating temperature: -40ºC - +60ºC | |
Globe-Thermometer: a. Measuring range: -40℃ to +60℃ b. Accuracy: <±0.3℃ ( –20 to +40℃ ) ; <±0.5℃ ( –40 to +60℃ ) c. Diameter: 150 mm ( included with a 111S-5 temp. probe ) d. Accessories: suspended wires & a mounting stand included e. Compatible dataloggers: HL10, HL20, DT12 and other brand of dataloggers f. Installation is easy and simple | |
111S Surface Temperature Probe: 111S Surface Temperature Probe: a. Measuring range: -40℃ to +60℃ b. Accuracy: ±0.3℃ ( -20℃ to +40℃ ) ±0.5℃ ( -40℃ to +60℃ ) c. For measurement of panel or leaf or other surface temperature | |
111S-H Surface or Panel Temperature Probe: 111S-H Surface Temperature Probe: a. Measuring range: -40℃ to +90℃ b. Accuracy: ±0.3℃ ( -20℃ to +40℃ ) ±0.5℃ ( -40℃ to +100℃ ) c. For measurement of panel or leaf or other surface temperature | |
IRR-P Infrared Radiometer: a. Field of View ( FOV ) : 22 ° half angle b. Accuracy : -15 to +60 °C ±0.2 °C absolute accuracy ±0.1 °C uniformity and repeatability -55 to +80 °C ±0.5 °C absolute accuracy ±0.3 °C uniformity and repeatability c. Wavelength Range : 8 - 14 um d. Response Time : Less than 1 second e.Operating Environment : -55°C to +80°C 0 - 100 RH ( non-condensing ) | |
111N Temperature probe: a. Measuring range: -40℃ to +60℃ b. Accuracy: ±0.3℃ ( -20℃ to +40℃ ) ±0.5℃ ( -40℃ to +60℃ ) c. For measurement of air, soil and water temperature | |
111H Temperature probe: a. Measuring range: - 40 ℃ to + 90 ℃ b. Accuracy: ± 0.3 ℃ ( - 20℃ to + 40 ℃ ) ± 0.5 ℃ ( - 40℃ to + 60 ℃ ) ± 0.7 ℃ ( + 60 ℃ to + 90 ℃) | |
LWS Leaf Wetness Sensor: a. Wet/Dry threshold : A defined resistance in K Ohm b. Time of Wetness : Wet fraction in datalogger's recording interval c. Power requirement: Excitation voltage ( 1 - 5 VDC ) d. Dimension: 11.5 cm ( L ) x 5.4 cm ( W ) e. Accessory: Stainless steel sensor mounting bracket included | |
SF AMP Sap Flow Converter: a. IN / OUT channel number: 3 b. Input range: -1000 to + 1000 uV c. Output range: -2000 to + 2000 mV d. Input channel type: Differential signal x 3 e. Output channel type: Single - ended signal x 3 f. Amplification: 2000 x ± 1 % g. Power supply: 8 - 24 VDC h. Power consumption: @ 15mA i. Enclosure: IP65 | |
TK-1 Rain gauge: a. Sensor type: tipping bucket b. Orifice diameter: 200 mm c. Material: Bronze d. Sensitivity: 0.5 mm e. Accuracy: below 20mm/hr ± 0.5mm 20mm/hr to 120 mm/hr ± 3% f. Signal output: none contact reed switch g. Housing: stainless steel h. Air bubble leveling included | |
ARG100 Aerodynamic rain gauge: a. Funnel diameter: 254 mm ( 10 inches ) b. Sensitivity: 0.2 mm per tip c. Output: contact closure d. Power requirement: None e. Air bubble for leveling included | |
6463M/I Rain gauges: a. Sensor type: tipping bucket b. Sensitivity: 0.2 mm ( M Series ) ; 0.01 inch ( I Series ) c. Output: contact closure d. Housing material: UV stabilized ABS plastic e. Power requirement: None f. Air bubble for leveling included g. Bird spikes included | |
260-700 Ultrasonic Water Level or Snow Depth Sensor: a. Measuring range: 0.5 to 10 meters b. Beam width: 22 degree c. Accuracy: ± 1cm or 0.4% distance to target d. Resolution: 3 mm e. Temperature range: -30 ℃ to +70 ℃ f. Analog output: 0 – 2 VDC or 0 – 5 VDC g. Power: 12 to 24 VDC, 50 mA | |
WL400 Submersible pressure transducers: a. Measuring range: 0 - 15' ( others: 0 - 30' , 0 - 60' , .... ) b. Burst Pressure: 10 * Full scale range c. Static accuracy: ± 0.2 % F.S.R. d. Power requirement: 10 - 36 VDC e. Housing Material: SS304L Stainless Steel f. Output: 0.4 to 0.2 VDC ( or 4 - 20 mA) g. Cable Length: 7.5M or 15M or 30M standard | |
720 Submersible pressure transducers: a. Measuring ranges: 0 - 5 through 0 - 300 psi b. Burst pressure: 2.0 * F.S. c. Static accuracy: ± 0.25% F.S.R. d. Power requirement: 9 - 30 VDC e. Wetted material: SS316 f. Operating temp. range: -10ºC to +60ºC g. Compensated temp.range: 0ºC to +50ºC h. Output: 0.4 to 2.0 VDC or 4 - 20 mA i. Circuit Protection: Polarity, surge/shorted output | |
PM-S20 & PM-S10 Solar panels: a. Max. power: 21Watt (PM-S20) ; 10Watt (PM-S10) b. Voltage at peak: 17.4 VDC (PM-S20) ; 16.8 VDC (PM-S10) c. Current at Peak: 1.21A (PM-S20) ; 0.74A (PM-S10) d. Optional USM 20 / USM 10 mounting bracke | |
200SS Watermark soil moisture sensor: a. Measuring range: 0 to 2 Bar ( 0 - 200 Centibars ) b. Fully solid state c. Will not dissolve in soil d. Linear accuracy even in moist soils ( below 50 Centibars ) e. Not affected by freezing temperatures f. Internal compensation for commonly found salinity levels | |
30KTCD-NL Watermark digital meter: a. Digital readout b. Converts electrical resistance reading to centibars c. Accuracy and stability d. One meter reads all watermark sensors | |
PSM Portable Soil Moisture Measurement System: a. Digital LCD display b. Measuring range: 0 – 100% VWC c. Accuracy and stability d. Included with AC/DC power supply and instrument case | |
AVM Portable anemometer: AVM-01 & AVM-03 a. Measuring range: 0 - 45 m / s ( 0 - 88 KNOTS, 0 - 100 MPH ) b. Accuracy: ± 3% c. Resolution: 0.1 d. Display: 3 1/2 digit LCD e. Operating temperature: 10℃ to 50℃ f. Power source: 9V battery g. Weight: 500g AVM-03 a. Temperature: 0 - 60℃ ( 32℉ - 140℉ ) b. Accuracy: ± 0.8℃ ( ± 1.5℉ ) | |
HT800 Portable thermo-hygrometer: a. Measuring range: Temperature: -15℃ - +60℃ Humidity: 5 - 98% b. Accuracy: Temperature: ± 0.2℃ ( ± 0.4℉ ) Humidity: ± 2.5% c. Resolution: Temperature: 0.1℃ ( 0.1℉ ) Humidity: 0.1% RH d. Display: digital LCD display e. Measuring rate: 2.5 per second f. Power source: 9V battery | |
LM-SS Portable Light Meter For Solar Sensors: a. Available sensors including: E20, LP02, SR11, PSP, LI-200S, CM3, E90, LI-190S, LI-210S, PIR, TUVR, CM4, CMP series, SP-Lite, NR-Lite, PAR Lite, CUV4 and other sensors with low signal outputs. b. A/D resolution: 16 bits c. Input range ( programmable ): ±200mV ( 10 uV resolution ) ±100mV ( 10 uV resolution ) ±50mV ( 10 uV resolution ) ±25mV ( 1 uV resolution ) ±12.5mV ( 1 uV resolution ) ±6.25mV ( 1 uV resolution ) d. Accuracy: 0.1% e. Display: LCD 4 digits with sign f. Battery: 2 AA alkaline g. Data logger memory: more than 3500 samples h. Data logger storage interval: 2..65535 seconds i. Accessories: carrying case, USB connection cable & software included | |
Sap Flow Monitoring System: a. Two-needle type of sap flow sensor b. Needle length: 33mm standard c. Heating ( constant current source ): 0.2 Watt d. Power : 12 VDC e. Data acquisition system | |